Skip to main content
Apollo NZ GlobalStart Flooring Brief
← Timber Sports FlooringATHREN

ATHREN COURT · TIMBER D1

Double-Batten Sprung Timber System

Deeper suspended birch sports-floor pathway using upper and lower timber batten layers separated by resilient pads, plus a lower levelling/shock-support layer.

158approx. mm nominal build height · adjustable
Supply-only project pathwayCurrent construction documents reviewedFIBA Level 2 evidence kept model-specificPerformance values held until test reports arrive

Documented build-up

Layer by layer.

Layer 01
A-class birch playing surface · current source shows approx. 20/22 mm × 60–80 mm × 1800 mm
Layer 02
0.5 mm EPE moisture-control membrane
Layer 03
19 mm solid-pine subfloor
Layer 04
45 × 45 mm upper solid-pine battens
Layer 05
8 mm intermediate resilient rubber pads at upper/lower batten intersections
Layer 06
45 × 45 mm lower solid-pine battens
Layer 07
19 mm lower resilient rubber levelling / shock-support layer
Overall height
Approx. 158 mm · adjustable
Installation type
Suspended timber sports-floor pathway

Competition evidence

FIBA status stays exact-system specific.

Current 2026 manufacturer documentation includes two fixed birch wooden-floor configurations with FIBA Approved Equipment Level 2 status. Exact ATHREN system-to-certificate mapping is confirmed before quotation. No Level 1 claim is made for this pathway from the current evidence.

ATHREN · technical diagrams

Two sprung timber systems, drawn as complete floor build-ups.

These original diagrams translate the current factory installation documents into a clean ATHREN planning language. They show documented layer order and nominal build heights, while disputed spacing and model-specific performance remain deliberately unlabelled.

T-01
SINGLE-BATTEN SYSTEM

Approx. 105 mm suspended build-up.

Birch playing surface over moisture control, solid-pine subfloor, timber battens and resilient rubber support.

BIRCH PLAYING SURFACE0.5 mm EPE MOISTURE LAYER19 mm SOLID-PINE SUBFLOOR45 × 45 mm PINE BATTEN19 mm RESILIENT PADCONCRETE BASEAPPROX. 105 mm · ADJUSTABLEPlanning reference only · final board thickness, resilient-pad spacing and adjustment range remain project-confirmed.
T-02
DOUBLE-BATTEN SYSTEM

Approx. 158 mm suspended build-up.

Two timber batten layers separated by intermediate resilient pads, over a lower resilient levelling layer.

BIRCH PLAYING SURFACE0.5 mm EPE MOISTURE LAYER19 mm SOLID-PINE SUBFLOORUPPER 45 × 45 mm BATTEN8 mm INTERMEDIATE PADLOWER 45 × 45 mm BATTEN19 mm LOWER RESILIENT PADAPPROX. 158 mm · ADJUSTABLEPlanning reference only · exact pad spacing, board thickness and certificate mapping remain project-confirmed.
T-03
BASE + EXPANSION COORDINATION

Slab flatness, expansion and ventilation belong in the same floor brief.

Current instructions document a ≤5 mm / 2 m base check, perimeter expansion, intermediate movement provisions and finished-floor ventilation.

2 m REFERENCE STRAIGHTEDGECURRENT SOURCE: ≤5 mm BASE DEVIATIONPERIMETEREXPANSION ZONEFINISHED-FLOOR VENTILATION PATHWAYPlanning reference only · final moisture testing, expansion layout and vent quantity follow site conditions and approved installation information.

Project-specific selection

Check the hall before freezing the floor.

Confirm slab flatness, moisture, finished floor level, underfloor services, equipment sockets, line marking, event use and local installation responsibilities.

Open Project Brief Installation Guide