Skip to main content
Apollo NZ GlobalStart Project Brief

SARENTA · STRUCTURAL INPUTS

Clear-span structure span, wind and foundation planning.

A 40 m span is not one structural problem. Wind, height, enclosure, openings, terrain, snow/seismic criteria and foundation conditions all change the reactions.

SHORT ANSWER

Use project design criteria to qualify the exact structure and reactions.

Provide span, height, enclosure, location and local design criteria before final structural selection. The selected system should then produce project calculations, drawings and support/anchor reactions for local foundation design.

KEY PROJECT POINTS

What should drive the decision.

These are project inputs, not substitute engineering or automatic product approvals.

01

Wind pressure depends on location, terrain and building geometry.

02

Enclosed structures can have different internal-pressure effects from open covers.

03

Snow and seismic requirements vary by destination.

04

Height can be as influential as span.

05

Anchoring/foundation reactions depend on the actual frame and envelope.

06

Ground/geotechnical conditions remain local inputs.

01

Define the design criteria

Project engineers should state relevant wind, snow, seismic and other structural criteria for the destination.

02

Keep configuration fixed during calculation

Changing doors, wall enclosure, height or span after structural design can invalidate earlier reactions.

03

Issue support reactions

The structure supplier should provide exact support/anchor loads for the local foundation engineer.

04

Coordinate erection conditions

Temporary stability, lifting and erection sequence should be planned separately from final in-service design.

PROJECT INPUTS

What to have ready before asking for the exact system.

A stronger brief shortens the gap between product interest and a useful technical/commercial response.

01

Location

02

Span

03

Length

04

Height

05

Open/enclosed

06

Envelope weight

07

Openings

08

Design wind

09

Snow if relevant

10

Seismic criteria

11

Ground/geotechnical data

12

Anchor/foundation strategy

EVIDENCE BOUNDARY

Published span capability is not project engineering.

Exact calculations, drawings, connections and reactions should be produced for the selected SARENTA configuration and design criteria, then coordinated with local foundations and approvals.

SARENTA Authority CentreEvidence, drawing and specification control for clear-span structures.

FAQ

Questions project teams usually need answered.

Can a published 60 m span be used anywhere?

No. Span capability depends on the exact system, geometry and project design criteria.

Who designs the foundations?

The local project engineer should use exact structure reactions to design foundations for the site unless another scope is expressly agreed.

Do open-sided covers have lower wind loads?

Not necessarily; open and enclosed structures behave differently and need proper engineering.

Project