Skip to main content
Apollo NZ Global
Get a QuoteMy Project
Start RHELGAN Project Brief
Medium sound-attenuated diesel generator configuration
RHELGAN Power & Energy SystemsRHELGAN Development & Humanitarian Systems

POWER & ENERGY SYSTEMS · 60 KVA CLASS

RHELGAN POWER 60

A project-configured generator system for international development, remote infrastructure and essential-service applications. Start from a proven standard configuration, then set the electrical, climate, control, enclosure and fuel package for the destination.

Direct project answers

What project teams need to know about RHELGAN POWER 60.

A concise answer layer covering application, evidence, configuration and project inputs.
01

What is RHELGAN POWER 60?

60 kVA class. Reference 50 Hz Perkins configuration: 60 kVA prime / 66 kVA standby, Perkins 1103A-33TG2, 14.6 L/h at full load. Final frequency, voltage,…

02

What projects are suitable for rhelgan power 60?

Typical project pathways include development infrastructure, remote communities, critical facilities, and international project power. Final suitability depends on the exact configuration, site conditions, operating requirements and destination.

03

What information is needed to specify rhelgan power 60?

Before specification or quotation, the project review should confirm: Verified product specifications or documented product facts; Clear applications, limitations and configuration boundaries; Project inputs required for manual quotation or technical review; Apollo supply-only scope and purchaser/local-project responsibilities. Claims are kept tied to the exact proposed system rather than transferred from a related product or reference configuration.

04

Can Apollo NZ Global supply rhelgan power 60 internationally?

Apollo can supply suitable projects internationally where the product and destination pathway are current. Send the project location, intended use, dimensions or quantities, timing, relevant drawings or photographs, and any known performance, compliance or environmental requirements for review.

REFERENCE PRIME60 kVA48 kW
REFERENCE STANDBY66 kVA53 kW
REFERENCE ENGINEPerkins 1103A-33TG250 Hz baseline
FULL-LOAD FUEL14.6 L/hReference @ 100% load

Reference configuration

A defined starting point, not a one-size-fits-all generator.

The figures below are based on a current 50 Hz Perkins-powered silent reference configuration from the manufacturing technical schedule. A final RHELGAN unit may change engine, alternator, frequency, voltage, enclosure, controller, tank, cooling and emissions configuration to suit the project country and duty.

Prime rating
60 kVA / 48 kW
Standby rating
66 kVA / 53 kW
Reference engine
Perkins 1103A-33TG2
Engine configuration
3 cylinders · 3.3 L displacement
Lubricating oil capacity
8.3 L
Fuel consumption
14.6 L/h at 100% load · reference configuration
Open-set dimensions
1.70 × 0.80 × 1.25 m
Open-set dry weight
890 kg
Open-set tank
115 L
Silent dimensions
2.30 × 1.10 × 1.24 m
Silent dry weight
1,370 kg
Reference silent tank
135 L
Frequency
50 Hz / 60 Hz · destination selected

Configuration capability

Build the power package around the site.

Standard systems first, with project-specific options added only where the operating environment or duty requires them.

50 Hz / 60 Hz configured to destination grid requirements
Single- and three-phase configurations where applicable
Open, silent, mobile and containerised formats
Automatic mains failure / ATS pathways
Deep Sea DSE7320 control available with remote-monitoring capability
Parallel and synchronised multi-generator systems available
Brushless AVR alternator with 100% copper windings; genuine Stamford or Leroy-Somer available
Standard fuel autonomy can be extended with larger or external tanks
High-ambient cooling options, including 50°C radiator configurations where technically suitable
Tropical, dusty and enhanced-corrosion packages selected to project exposure
Solar + battery generator-backup integration available as a project-engineered pathway
RHELGAN project branding available on production units and documentation

Typical applications

Designed for essential services and difficult destinations.

01

Community facilities + schools

02

Small developments + amenities

03

Workshops + project compounds

04

Distributed infrastructure loads

Electrical configuration

Frequency, voltage, phase, earthing, protection and connection arrangement are set from the destination grid and project brief.

Controls + ATS

Manual, AMF and ATS pathways are available, with DSE7320 control and remote-monitoring capability where selected.

Climate + enclosure

Silent, weatherproof, high-ambient, dusty-environment and enhanced-corrosion packages are selected against actual exposure.

Hybrid + parallel

Generator backup can be coordinated with solar PV, battery storage or synchronised multi-set systems through a project-specific control architecture.

Quote release bundle

The rating is only useful when the exact generator package follows it.

Before a RHELGAN POWER class becomes a project order, the quoted configuration should carry these technical, logistics and lifecycle controls with it.

Approved project datasheet with prime / standby basis, voltage, phase and frequency
Exact engine, alternator, controller, ATS and enclosure configuration
Load schedule and motor-start / transient review supplied by the project team where relevant
Ambient-temperature, altitude, corrosion and enclosure package confirmed for the destination
Fuel-tank, runtime, filling, bunding and local fuel-system responsibilities
Noise, emissions and certification evidence matched to the exact quoted configuration
Packing, dry weight, lifting points, unloading and site-access requirements
Commissioning, manuals, recommended spares, warranty and service responsibility
Project specification control

RHELGAN POWER model names are planning classes. Published reference figures are not a substitute for final electrical-load analysis, motor-start review, local compliance, site engineering or the approved project datasheet. Noise performance, emissions, ambient derating, altitude derating, corrosion package, warranty and certifications are confirmed for the exact quoted configuration.

RHELGAN · POWER & ENERGY SYSTEMS

Tell us where the generator is going and what it needs to keep running.

Start RHELGAN Project Brief View the power range
Project