Skip to main content
Apollo NZ GlobalStart RHELGAN Project Brief
Large sound-attenuated diesel generator configuration
RHELGAN Power & Energy SystemsRHELGAN Development & Humanitarian Systems

POWER & ENERGY SYSTEMS · 150 KVA STANDBY CLASS

RHELGAN POWER 150

A project-configured generator system for international development, remote infrastructure and essential-service applications. Start from a proven standard configuration, then set the electrical, climate, control, enclosure and fuel package for the destination.

REFERENCE PRIME135 kVA108 kW
REFERENCE STANDBY150 kVA120 kW
REFERENCE ENGINEPerkins 1106A-70TG150 Hz baseline
FULL-LOAD FUEL30.28 L/hReference @ 100% load

Reference configuration

A defined starting point, not a one-size-fits-all generator.

The figures below are based on a current 50 Hz Perkins-powered silent reference configuration from the manufacturing technical schedule. A final RHELGAN unit may change engine, alternator, frequency, voltage, enclosure, controller, tank, cooling and emissions configuration to suit the project country and duty.

Prime rating
135 kVA / 108 kW
Standby rating
150 kVA / 120 kW
Reference engine
Perkins 1106A-70TG1
Engine configuration
6 cylinders · 7.01 L displacement
Lubricating oil capacity
16.5 L
Fuel consumption
30.28 L/h at 100% load · reference configuration
Open-set dimensions
2.35 × 0.95 × 1.52 m
Open-set dry weight
1,480 kg
Open-set tank
270 L
Silent dimensions
2.80 × 1.10 × 1.47 m
Silent dry weight
1,880 kg
Reference silent tank
210 L
Frequency
50 Hz / 60 Hz · destination selected

Configuration capability

Build the power package around the site.

Standard systems first, with project-specific options added only where the operating environment or duty requires them.

50 Hz / 60 Hz configured to destination grid requirements
Single- and three-phase configurations where applicable
Open, silent, mobile and containerised formats
Automatic mains failure / ATS pathways
Deep Sea DSE7320 control available with remote-monitoring capability
Parallel and synchronised multi-generator systems available
Brushless AVR alternator with 100% copper windings; genuine Stamford or Leroy-Somer available
Standard fuel autonomy can be extended with larger or external tanks
High-ambient cooling options, including 50°C radiator configurations where technically suitable
Tropical, dusty and enhanced-corrosion packages selected to project exposure
Solar + battery generator-backup integration available as a project-engineered pathway
OEM RHELGAN branding available on production units and documentation

Typical applications

Designed for essential services and difficult destinations.

01

Clinics + community health

02

Schools + training facilities

03

Water + wastewater infrastructure

04

Camps + community hubs

Electrical configuration

Frequency, voltage, phase, earthing, protection and connection arrangement are set from the destination grid and project brief.

Controls + ATS

Manual, AMF and ATS pathways are available, with DSE7320 control and remote-monitoring capability where selected.

Climate + enclosure

Silent, weatherproof, high-ambient, dusty-environment and enhanced-corrosion packages are selected against actual exposure.

Hybrid + parallel

Generator backup can be coordinated with solar PV, battery storage or synchronised multi-set systems through a project-specific control architecture.

Project specification control

RHELGAN POWER model names are planning classes. Published reference figures are not a substitute for final electrical-load analysis, motor-start review, local compliance, site engineering or the factory-approved project datasheet. Noise performance, emissions, ambient derating, altitude derating, corrosion package, warranty and certifications are confirmed for the exact quoted configuration.

RHELGAN · POWER & ENERGY SYSTEMS

Tell us where the generator is going and what it needs to keep running.

Start RHELGAN Project Brief View the power range
Project