Skip to main content
Apollo NZ GlobalBuild project brief

CIVARO Hydration · Specifier Centre

Compare the station. Define the interfaces. Then freeze the specification.

This centre gives architects, landscape architects, councils, schools, sports planners, developers and procurement teams one place to compare the four priority CIVARO Hydration platforms and identify the information required before quotation.

Factory product reference for a combined outdoor bottle filler, drinking fountain and pet hydration station
CIV-CB01

CIVARO COMBI 01

Bottle filling + drinking + pet hydration

Technical product page
Factory product reference for a stainless-steel pedestal bottle-filling and drinking station
CIV-F01

CIVARO FILL 01

Bottle filling + drinking station

Technical product page
Factory product reference for a wheelchair-accessible stainless-steel public drinking fountain
CIV-A01

CIVARO ACCESS 01

Accessible public drinking fountain

Technical product page
Factory product reference for a combined human and pet outdoor drinking fountain
CIV-C01

CIVARO COMPANION 01

People + pet public hydration

Technical product page

Comparison matrix

Four platforms, different jobs.

The matrix is a selection aid, not a blanket compliance statement. Exact fittings, certifications and project options remain tied to the selected configuration.

AttributeCOMBI 01FILL 01ACCESS 01COMPANION 01
Primary role

Bottle + drink + pet

Bottle + drink

Accessible drinking

People + pet

Current material

304 stainless steel

304 stainless steel

304 stainless steel

304 stainless steel

Bottle filling

Yes

Yes

No in base reference

No in base reference

Direct drinking

Yes

Yes

Yes

Yes

Pet bowl

Yes

No

No

Yes

Accessible pathway

Project option

Project review

Primary pathway

Project review

Filtration pathway

Reference includes filter

Reference includes filtration option

Project option

Project option

Cooling pathway

Project option

Factory cooling option shown

Project option

Project option

Coastal 316 / 316L

Project qualification

Project qualification

Project qualification

Project qualification

Best starting applications

Parks · trails · waterfronts

Schools · sport · public buildings

Civic · school · recreation

Parks · dog areas · trails

Minimum project data

What a useful hydration RFQ should contain.

Supplying this information early reduces assumptions and makes factory confirmation, technical review and quotation much more efficient.

01Project country and jurisdiction
02Site type and expected users
03Station quantity and locations
04Direct drinking / bottle filling / pet function
05Accessible-use requirements
06Potable-water connection and pressure
07Waste and drainage route
08Filtration requirement
09Cooling requirement and available power
10Exposure: inland / coastal / salt / high wind
11Material and finish direction
12Foundation / anchoring information
13Drawings, BOQ or specification status
14Required certificate / submittal package
15Maintenance, filter and spare-parts strategy

Evidence framework

Three levels of information.

01

Documented now

Current product dimensions, 304 stainless-steel references, base functions and selected factory accessories shown in the CIVARO technical record.

02

Confirm for configuration

Water pressure, flow, exact filter, cooling, electrical frequency, anchoring, service access, controls and finish schedule.

03

Verify for destination

Accessibility, sanitary / potable-water certification, 316 / 316L coastal package, corrosion evidence and jurisdiction-specific compliance.

Tender wording starter

Keep the specification functional and evidence-based.

Provide the selected CIVARO Hydration station in the documented project configuration, complete with agreed drinking, bottle-filling and/or pet-hydration functions. Submit product dimensions, material and finish schedule, plumbing and drainage requirements, fixing details, maintenance information and all project-required model/component certification before final approval. Accessibility and coastal requirements shall be verified for the exact supplied configuration and destination.

This is a planning clause only. The appointed project consultant should edit it to suit the contract, jurisdiction and site.

Application pathways

Go deeper by project type.

Use the application pages when the buying question is driven by the place rather than a specific CIVARO model.

Wholesale & project supply

Turn the matrix into a project-specific hydration schedule.

Use the CIVARO brief builder to capture quantity, functions, users, accessibility, filtration, cooling, water, drainage, power, exposure and evidence requirements.

Build hydration project brief

Market pathways

Move between regions without losing the project context.

Choose the regional hub first, then the country where a dedicated pathway exists. Product suitability, documentation, freight and local project responsibilities are still confirmed against the actual site.

Project