Apollo NZ GlobalDiscuss a Project

Architects · façade consultants · specifiers · contractors

Specifier & Tender Centre

Use this layer to compare façade families, structure an RFQ, develop concept details, plan finish approvals and prepare evidence-safe tender wording before a manufacturing system is frozen.

Build façade RFQ

01 · System selection matrix

Compare the design role before choosing the product family.

This matrix is for early specification and design-team discussion. It does not rank systems or replace project engineering.

SystemVisual roleTypical applicationVentilationShaping potentialWeight considerationKey review
Solid aluminiumClean, precise, monolithicCommercial, civic, transport, soffitsBehind-panel cavity where designedHigh — folded, faceted, selected curvedLight-to-moderateAlloy, thickness, stiffening, subframe, finish, fire and wind evidence
Perforated aluminiumPattern, transparency, solar controlParking, transport, education, plant screeningHigh open-area potentialHigh — flat, folded, selected curvedLight-to-moderateOpen area, edge distances, stiffness, pattern, wind, framing and finish
Laser-cut screensGraphic, bespoke, high-identityHospitality, entrances, privacy, feature façadesPattern-dependentHigh — flat and folded pathwaysMaterial / gauge dependentPattern integrity, climbability, wind, frame, cut edges and finish
Fins & battensRhythm, depth, strong shadowOffices, hotels, education, sun controlOpen systemProfile-ledProfile / spacing dependentProfile span, support centres, thermal movement, wind and fixing visibility
Honeycomb panelsVery flat, large-formatTransport, canopies, soffits, premium façadesBehind-panel cavity where designedFlat and selected shaped formsLow relative to large panel areaFace sheets, core, edge construction, bond evidence, fire and supports
Mesh / expanded metalOpen, layered, industrial-refinedParking, sports, plant and infrastructureVery highPattern / frame dependentSystem dependentAperture, orientation, edge treatment, tension/support, impact and corrosion
Weathering steelWarm patina, material depthCivic, cultural, landscape-integrated architectureSystem dependentHigh for plate / folded formsModerate-to-heavyMaterial grade, runoff, coastal exposure, drying cycles and galvanic compatibility
UHPC / architectural concreteMineral, sculptural, monolithicCivic, cultural, hospitality, feature envelopesRainscreen pathway where designedVery high via moulded geometryHigher — lifting strategy importantMix, reinforcement, anchors, weight, joints, water, structural and seismic evidence

02 · Concept detail library

Resolve the junctions that make the façade look deliberate.

These detail types define what needs coordination. They are intentionally conceptual until the actual system, substrate and local engineering are known.

Conceptual façade fixing and panel-joint study
01

Vertical panel joint

Coordinate joint width, shadow line, movement and drainage with panel edges and rails.

02

Horizontal panel joint

Resolve water-shedding logic, panel returns, support and visual alignment.

03

External corner

Compare folded returns, expressed joints, corner cassettes and trim pathways.

04

Internal corner

Maintain drainage, access and intentional joint geometry through recesses.

05

Window reveal

Coordinate jamb, head and sill interfaces with windows, membranes and drainage.

06

Parapet / top termination

Resolve capping, cavity closure, ventilation and water management.

07

Base / lower termination

Define drainage, clearances, impact exposure and cavity closure at the bottom edge.

08

Soffit transition

Carry material rhythm through horizontal surfaces while coordinating lighting and services.

09

Fin / batten support

Coordinate blade depth, spacing, support centres, movement and concealed / expressed fixings.

10

Curved panel zone

Set radius, segmentation, joint rhythm, tolerances and transport constraints early.

03 · Finishes & materials centre

Approve appearance with samples, not assumptions.

Finish names below describe design pathways. Exact chemistry, coating supplier, exterior rating, warranty and colour tolerance stay tied to the selected production system.

Solid colour coating

Project-selected colour; exact coating system and warranty confirmed per manufacturing pathway.

Metallic coating

Metallic appearance requires sample approval and consistent production orientation.

Anodised pathway

Where available for the selected aluminium system; colour and finish variation need sample control.

Wood-look finish

Decorative architectural finish pathway subject to exact production method and exterior suitability.

Stone-look finish

Decorative lightweight visual pathway where supported by the selected system.

Weathering steel

Natural patina pathway with runoff, adjacent surfaces and exposure reviewed carefully.

UHPC mineral finish

Smooth, textured or pigmented pathways depend on mould, mix and sample approval.

Custom texture / pattern

Project-developed textures, reliefs and perforation patterns subject to manufacturability review.

04 · Sample & mock-up pathway

Move from colour chip to production release in controlled steps.

Not every project needs every stage. The project team can scale the process to façade complexity, visual sensitivity and procurement risk.

01Finish / colour sample
02Material or perforation sample
03Corner / joint prototype
04Project façade mock-up
05Design-team approval
06Controlled production release

05 · Tender wording

Generic clauses that preserve the project-specific checks.

These clauses can be copied into early tender or specification documents and then completed by the project team once verified system data is available.

01

Architectural aluminium façade — generic clause

Provide a project-specific architectural aluminium façade system comprising formed aluminium panels, coordinated support rails / brackets, project-required trims and fixings, and the approved finish. Final alloy, temper, panel thickness, stiffening, joint geometry, subframe, anchors, coating system and performance evidence shall be confirmed against the selected manufacturing system and project structural / building-envelope requirements before production.

02

Perforated architectural screen — generic clause

Provide custom perforated architectural façade / screening panels to the approved pattern, open-area intent and finish. Panel geometry, gauge, edge distances, structural support, wind performance, frame centres, drainage, access and public-safety considerations shall be developed for the specific project. Pattern artwork and finish samples shall be approved before production release.

03

UHPC / GFRC façade — generic clause

Provide project-specific UHPC / GFRC architectural façade elements to the approved geometry, texture and colour intent. Final material specification, reinforcement, panel thickness, weights, lifting points, anchors, support structure, joints, tolerances, water management, structural / seismic performance and test evidence shall be confirmed for the selected system and destination before manufacture.

04

Samples and mock-up — generic clause

Submit representative finish / material samples for approval before production. Where required by the project documentation, provide a physical mock-up or prototype sufficient to review panel appearance, joint intent, corner / interface conditions and buildability. Sample or mock-up approval does not replace project engineering, statutory review or final production drawing approval.

Important: these are generic project-intent clauses, not certified specifications. Final structural, fire, moisture, thermal, seismic, coating and local-code requirements remain the responsibility of the appointed project professionals and selected verified system.

06 · Application pathways

Specification changes with the building type.

Each application page frames the system choices and early coordination issues without turning representative imagery into an Apollo completed-project claim.

Transport architectureAirports & Transport

Large, highly visible envelopes where repeatability, durability, ventilation, solar control and coordinated maintenance access matter.

Open application
Hospitality architectureHotels & Resorts

Guest-facing façades where privacy, shade, material character and premium detailing need to work with coastal or high-exposure conditions.

Open application
Schools · universities · learningEducation & Campus

Robust façade and screening systems for learning environments, campuses and shared public spaces with strong daylight and lifecycle requirements.

Open application
Public architectureCivic & Cultural

High-identity public buildings where sculptural form, material depth, long-life detailing and strong civic presence are central to the brief.

Open application
Retail · mixed-use · precinctsRetail & Mixed Use

Layered façades, screens and feature zones that help manage identity, services, shade, tenancy variation and pedestrian-scale experience.

Open application
Workplace architectureCommercial Offices

Precise architectural envelopes for offices and headquarters where clean panel geometry, solar response and repeatable detailing drive the result.

Open application
Arenas · aquatic · community facilitiesSports & Recreation

Ventilated, durable and high-impact architectural skins for large-span recreation and sporting buildings with demanding public use.

Open application
Residential · multi-residentialPremium Residential

Refined cladding and screening for premium homes and multi-residential projects where privacy, material junctions and close-range detailing matter.

Open application

Ready for project review?

Turn the specification intent into an RFQ.

Build the façade brief first, then upload the current plans, elevations, sections or BIM/CAD files.

Build project / RFQ brief Upload drawings