Socketed Competition Posts
Permanent floor-sleeve pathway for dedicated and higher-level courts where the floor build-up and structural interface can be coordinated before installation.
Start Volleyball Brief
VOLLEYBALL EQUIPMENT · TECHNICAL CENTRE
LUTHVAR VOLLEYBALL · TECHNICAL CENTRE
One public technical workspace for socketed and portable posts, nets, antennae, tensioning, protection, referee systems, multi-court storage and FÍSVOR. Published specifications use LUTHVAR naming; exact equipment evidence is matched after the hall and event pathway is defined.
EQUIPMENT FAMILIES
These families describe how the equipment works inside the hall while keeping posts, sleeves / bases, nets, protection and officials equipment tied to their real floor and event interfaces.
Permanent floor-sleeve pathway for dedicated and higher-level courts where the floor build-up and structural interface can be coordinated before installation.
Mobile pathway for schools, training centres and shared halls where permanent sockets are undesirable or frequent court relocation is required.
Matched net package covering net body, antennae, pockets, tensioning hardware and post interface rather than treating the net as a standalone item.
Protective system matched to the post profile, court free-zone strategy and equipment operating method.
Referee platform, scorer and officials equipment coordinated with the free zone, post position, sightlines and storage.
Height-adjustable and teaching pathways for schools and academies where mixed ages, supervision and quick setup matter.
Racks, trolleys and dedicated storage bays for posts, nets, padding and referee equipment across larger court banks.
Scoring, match information, main displays and repeaters coordinated separately from the physical court-equipment approval pathway.
TECHNICAL SELECTION MATRIX
The matrix separates school, club, competition and arena pathways while keeping exact approval, homologation and product evidence tied to the system that will actually be supplied.
| Equipment family | Installation pathway | Movement / storage | Key interfaces | Evidence gate | School | Club | Competition | Arena |
|---|---|---|---|---|---|---|---|---|
| 01Socketed competition post systemsLUTHVAR | Floor-sleeve / socket pathway integrated with the sports-floor build-up | Posts remove after play; sleeves remain as permanent floor interfaces | Sleeve depth, slab / subfloor, floor finish, net loads, cap detail, court geometry | Exact post, sleeve and competition evidence matched to the selected system | Recommended | Core | Exact evidence | Exact evidence |
| 02Portable / weighted post systemsLUTHVAR | Floor-standing mobile pathway without permanent court sockets | Move to dedicated storage / parking after use | Base footprint, ballast, floor protection, free zone, handling route, stability | Exact stability, use-level and competition suitability confirmed by system | Core | Recommended | Project-specific | Project-specific |
| 03Net, antennae + tensioning packageLUTHVAR | Matched to selected post spacing, post geometry and use level | Removed, rolled and stored after play where the hall changes sport | Net height, tension path, cable / strap hardware, post load, antenna pockets | Exact net and accessory construction matched to the required competition pathway | Core | Core | Exact evidence | Exact evidence |
| 04Post padding + player protectionLUTHVAR | Matched protective system around each selected post configuration | Removes or travels with the post depending on equipment type | Post profile, free-zone intrusion, attachment, finish, cleaning and storage | Exact padding fit and material evidence checked against project requirements | Core | Core | Core | Core |
| 05Referee stands + officials equipmentLUTHVAR | Courtside platform / stand positioned outside the required playing envelope | Mobile or demountable with dedicated storage position | Free zone, post / net position, scorer sightline, padding, floor protection | Exact event suitability and protective details confirmed for the supplied stand | Option | Recommended | Exact evidence | Exact evidence |
| 06Training + adjustable-height systemsLUTHVAR | Socketed or portable pathway selected around age group and timetable | Designed for repeat setup, height changes and shared-hall storage | Adjustment range, supervision, net tension, floor sockets / bases and storage | Age-group, local rules and safe operating method control selection | Core | Option | — | — |
| 07Multi-court storage + transport systemsLUTHVAR | Dedicated racks / trolleys / storage bays sized to the court count | Posts, nets, padding and referee equipment move along planned handling routes | Door widths, floor protection, storage depth, divider zones, court-changeover time | Project-specific handling plan rather than a competition approval claim | Recommended | Core | Recommended | Recommended |
| 08FÍSVOR scoring + venue informationFÍSVOR | Courtside, wall, suspended or arena-display pathway | Fixed or event-configured depending on the hall | Power, data, scorer table, sightlines, main display, repeater and control positions | Competition protocol and exact product evidence checked separately from court equipment | Option | Recommended | Exact evidence | Exact evidence |
EVIDENCE GATE
The public pathway narrows the technical family. The exact system is released only after court geometry, floor interfaces, operating method and event evidence are matched to the real project.
Freeze court count, spacing, free zones, divider lines and scorer / spectator positions.
Confirm ATHREN floor build-up, sockets / sleeves or portable-base pathway before product release.
Confirm target net heights, tensioning, daily changeover, referee equipment and storage routine.
Match posts, sleeves / bases, nets, padding and referee systems to the exact project and event pathway.
Close scoring, power/data, installation scope, documentation, testing and destination requirements.
INTERFACE LOGIC
Socketed and portable systems solve different problems. Net tension, free-zone control, divider paths, officials equipment and storage all need to be resolved around the selected pathway.
Coordinate sleeve depth, fixing / support, finished floor, removable caps, tolerance and long-term access before the floor is completed.
Confirm base footprint, ballast, movement route, floor protection, free-zone intrusion and storage before selecting the system.
Treat net, antennae, tension hardware and post geometry as one assembly so the load path and operating method remain compatible.
Size storage for the real number of posts, nets, pads and referee stands and protect the movement route through doors and shared-hall zones.
QUOTE-RELEASE CHECKLIST
Enough information is needed to avoid a post or socket solution that conflicts with the floor, divider layout, free zone or storage plan.
Project use level and intended competition / event pathway
Court count and whether courts operate concurrently
Hall plan with free zones, dividers, seating and scorer positions
ATHREN / existing floor build-up and slab information where available
Socketed, portable or recommendation-required post pathway
Required net-height range and any junior / training operation
Post, net, padding and referee-equipment storage location
FÍSVOR scoring, match information and main-display requirements
Destination, programme and installation responsibility
A professional post, net or referee system is not automatically suitable for a named competition because another similar product is approved. Exact current evidence is checked against the system that will actually be supplied.
NEXT STEP
The technical matrix narrows the equipment family. The Volleyball Hall Brief adds court count, clear height, floor, dividers, spectators, FÍSVOR and storage so Apollo can move into exact controlled selection.