TREVIK · WEATHER PERFORMANCE

Architectural opening wind, air and water performance.

A door can look identical in two projects but face very different wind pressure, rain exposure and building-envelope consequences.

SHORT ANSWER

Match tested/calculated evidence to the exact size, configuration and exposure.

Define project design pressure and weather exposure first, then verify the selected TREVIK system's exact configuration evidence. Do not extrapolate a generic test beyond its panel size, support, hardware or pressure scope without engineering.

KEY PROJECT POINTS

What should drive the decision.

These are project inputs, not substitute engineering or automatic product approvals.

01

Wind pressure depends on site/building conditions.

02

Air leakage and water penetration are different performance metrics.

03

Large openings can exceed tested panel/frame sizes.

04

Threshold/drainage detail strongly affects water performance.

05

Operable panel seals and hardware condition affect lifecycle performance.

06

Storm/security shutters require their own exact evidence.

01

Start from project pressure

The building engineer/envelope consultant should define relevant pressure/exposure requirements for the actual opening location.

02

Read the test scope

Check specimen size, panel arrangement, pressure sequence, support/fixings and pass criteria before using a report.

03

Coordinate drainage

Sills, tracks, weeps, external falls, canopies and adjacent waterproofing can be as important as the door panel.

04

Plan maintenance

Seals, rollers, tracks, drains and adjustments should have an inspection/cleaning regime because performance can deteriorate with wear and debris.

PROJECT INPUTS

What to have ready before asking for the exact system.

A stronger brief shortens the gap between product interest and a useful technical/commercial response.

01

Opening location

02

Design pressure

03

Exposure/rain

04

Opening size

05

System type

06

Panel configuration

07

Threshold

08

External drainage

09

Glazing/panel material

10

Fixing substrate

11

Maintenance access

12

Local envelope consultant

EVIDENCE BOUNDARY

A test report only proves what was actually tested.

Keep test specimen size, configuration, pressure, support condition and standard visible. Use project engineering where the actual opening falls outside the verified scope.

TREVIK Project Authority CentreEvidence and drawing-control framework for architectural openings.

FAQ

Questions project teams usually need answered.

Does a wind rating prove water tightness?

No. Structural wind, air leakage and water penetration are separate performance questions.

Can a test on a smaller door prove a larger door?

Not automatically. Size and configuration changes may require engineering or further evidence.

Why does threshold design matter?

Tracks/sills can collect water; drainage and adjacent waterproofing must be coordinated with the exact system.

Project