Match the use
Roof, solar control, façade or enclosure—these are not interchangeable
Apply as a reseller Architectural resellers win customer confidence by specifying the right system for the actual site—not by advertising the largest possible span or an unqualified wind rating. This guide helps distributors, façade firms and shade contractors prepare an accurate project-to-wholesale supply brief.
Before quoting an architectural system, distinguish the operating mechanism, structural support, site exposure, material/finish, water management and locally required verification. Different louvre, glass, façade and screen families need separate product evidence.
Roof, solar control, façade or enclosure—these are not interchangeable
Spans, structural connections, mounting geometry and drainage
Model-specific wind/load, material and safety documentation
Engineering, installation, electrical integration and approvals
A good first brief states what the building needs to do, rather than naming a preferred product by appearance.
For an outdoor roof, determine whether the blades rotate in place, physically retract to uncover the sky, or form a fixed weather covering. For a façade, determine whether the objective is solar control, ventilation, privacy, appearance, rain screening or another documented function. For side screens and glass, clarify whether the enclosure needs airflow, weather resistance or acoustic separation.
Ask how the client will use the space: a residential terrace, café, resort, school circulation area and commercial building façade may have very different maintenance, access and safety requirements. Note whether the area is occupied during high wind or rain and whether it must function as a fully enclosed room.
Separate marketing language from operating mechanics. A tilting-blade pergola is not necessarily retractable, and a sunshade is not automatically a watertight building envelope. Selection begins with the physical behaviour and actual project expectations.
Never promise a weatherproof or cyclone-rated enclosure based on a generic product-family headline.
Architectural systems fail commercially when the quotation ignores what they attach to.
Record clear width, projection, finished height, slope, support positions, roof drainage direction, clearance for doors and other fixed building features. Distinguish internal clearances from overall outside dimensions. If dimensions are preliminary, label them as such so the manufacturer does not treat them as an order-ready schedule.
For existing buildings, determine whether the local designer has reviewed the supporting structure and fixing substrate. A powder-coated aluminium roof still transfers wind and gravity loads to beams, posts, anchors and foundations. Wider spans or fewer posts may require completely different engineering or hidden steel support.
Drainage is a coordinated building detail: roof collection, post downpipes, outlets, surface discharge and local stormwater arrangements must work together. A system with integrated gutters does not by itself confirm downstream drainage capacity or compliance.
Do not transplant a nominal span from another model or configuration without manufacturer and site-specific confirmation.
Appearance influences the sale; durability and maintenance affect the long-term customer relationship.
Choose a finish based on environment, expected life, cleaning access and the exact supplier specification. Coastal exposure, chemical cleaning, salts and industrial pollutants may materially change coating or hardware selection. Ask for the approved finish and warranty conditions; a custom colour may change price or lead time.
Record whether screens, shutters, glazing, lighting, heaters, sensors, fans or controls must be integrated. Confirm the technical compatibility of each accessory with the selected roof and whether it belongs to the same product supplier. Electrical circuits, waterproof junctions and commissioning still require local planning.
For façade products, distinguish decorative cladding, operable louvres, glass systems and building-envelope interfaces. Different products may have separate performance evidence, proprietary fixings, tolerances and fire or safety review requirements. Avoid cross-brand performance claims.
An option listed on a brochure is not proof of approval with every roof size, façade type or destination.
Only documents for the selected product and configuration can support its technical promises.
Request the current product datasheet, drawings, operating instructions, material and coating descriptions, applicable test evidence and any available engineering scope. Match document model numbers against the actual quoted system, including blade size, profiles, fixing types and accessory configuration.
The local design and approving professionals determine which project-specific checks are needed: structural, wind actions, fire performance, glazing safety, electrical interfaces or other matters. International test methods may not directly satisfy the destination code without further assessment.
Ask the supplier what is verified, what must be engineered locally, and what remains unconfirmed. That distinction protects both the reseller and the customer and avoids converting a marketing claim into an unsupported contractual guarantee.
A technically useful brief can be short, provided the critical interfaces are stated.
Include site location, building type, roof or façade purpose, dimensions, finish, mounting and structural assumptions, operation method, accessory list, delivery city, current project stage and intended quotation date. Attach sketches rather than describing a complex site entirely in text.
For an established reseller, state who will hold the customer contract and who provides local surveying, engineering, install coordination, commissioning and maintenance support. If you are supplying one resort project rather than building inventory, say so; a project-specific wholesale quotation may be appropriate.
Review the public Apollo product and technical pages first. ARKEN and CADARN architectural/outdoor families have different capabilities and limits. Other façade and shade products follow their own specifications, documentation and manufacturer permissions.
The strongest local partners do more than forward photos and ask for discounts.
Maintain a method for collecting consistent site dimensions, reviewing actual product evidence and resolving technical questions before committing to the end customer. A practical sales team can explain why a kitset may be inappropriate for a complex commercial site and when engineering input is essential.
Set clear service expectations for customers: what is supplied, what is locally installed, how spares are ordered, how maintenance is arranged and who handles warranty assessment. Keep a written record of any approved brand-use or territory arrangement.
Apollo welcomes credible architectural and outdoor-system resellers in suitable markets. A trade application starts a human review of company capability, products and destinations. It does not confer exclusive representation or permission to make unsupported performance claims.
Keep your first application concise. Apollo will request the detailed technical and commercial information when the product and destination are suitable for further review.
Send your wholesale applicationNo. The relevant wind evidence depends on the specific model, configuration, fixings and local project. Verify site-specific requirements before offering the system.
No. Rotating blades remain overhead while a retracting roof moves components away to open more sky. The systems require different drawings and operating specifications.
Only when the exact supplier, system and configuration support that combination. Confirm electrical, fixing, drainage and warranty implications.
A project-specific arrangement may be considered. The product, destination, local technical duties and commercial terms must be accepted first.
Your company manages its customers and resale pricing. Apollo reviews the specific product, location and wholesale scope before accepting orders.