Skip to main content
Apollo NZ Global

LUTHVAR · GLOBAL SPORTS TECHNICAL LIBRARY

Football
Facility Specification Pack

A football ground is a surface system, civil/drainage project, equipment package, lighting project and spectator venue at the same time. This centre connects those layers without treating a turf certificate as a complete stadium approval.

OWNERApollo NZ Global · LUTHVAR
COMMERCIAL MODELWholesale & Project Supply · Supply-only
TECHNICAL OWNERFootball Facility Technical Centre
PROJECT PATHProject Brief
01

PROJECT INTENT

Define the facility level before selecting systems.

01Schools · councils · participation

Community / education

Community field with durable surface, goals, containment, training lighting and simple operations.

02Clubs · academies · universities

Club / academy

Club ground with match equipment, dugouts, stronger lighting, spectators and maintenance.

03Regional · national competition

Competition

Regional competition venue with higher field/equipment evidence, grandstand, display/audio and event operations.

04International · professional · broadcast

Elite / major venue

Professional stadium pathway with FIFA-level field requirements, broadcast lighting, major spectators, media and high-performance operations.

02

TECHNICAL REQUIREMENTS

Twelve coordination clauses for the complete facility.

01

geometry

Field dimensions, run-offs, technical areas, goal positions, perimeter and spectator zones must follow the intended competition and local governing requirements.

02

surface

Compare natural, hybrid and artificial turf around hours of use, climate, maintenance capability, drainage, shock/performance and certification target.

03

equipment

Goals, nets, anchors, corner flags, team shelters and training equipment need exact-model safety/performance evidence and local foundation interfaces.

04

lighting

Training, competition and broadcast levels require different photometric design, glare/spill control, pole/roof structure and camera coordination.

05

spectators

Separate teams/officials, spectators, accessible viewing, grandstands, hospitality and media without compromising safety zones or field maintenance access.

06

structure

Coordinate goal foundations, fencing/netting, floodlight structures, scoreboards, spectator roofs, pavilions and field-service routes.

07

environment

Rainfall, heat, frost, wind, salt exposure and irrigation water quality affect surface design, drainage and maintenance.

08

accessibility

Accessible spectator circulation, viewing, amenities and community/player access should be integrated at precinct level.

09

storage

Goals/training equipment, maintenance machinery, infill/repair materials, spare seats and match-day systems need secure storage and vehicle access.

10

technology

FÍSVOR score/video, HLJÓÐ audio, cameras, VAR/analysis where required, timing, network and control should be coordinated with sightlines and structures.

11

evidence

FIFA distinguishes laboratory testing from installed-pitch field testing and awards FIFA QUALITY / FIFA QUALITY PRO to pitches meeting the relevant programme.

12

lifecycle

A turf asset needs mowing/grooming/brushing/decompaction/infill or natural-turf agronomy, irrigation/drainage care, testing, repairs and usage control.

03

PROJECT INPUT SCHEDULE

Information to obtain before the exact system is released.

01

Competition level

02

Field dimensions

03

Natural / hybrid / artificial pathway

04

Use hours

05

Base / drainage / irrigation

06

FIFA certification target if any

07

Goals / shelters / containment

08

Lighting level

09

Spectator capacity

10

Display/audio/camera systems

11

Maintenance resources

04

DRAWING & SUBMITTAL ROADMAP

Draw the interfaces that can create procurement errors.

01

Field + run-off plan

Planning reference first. Exact fabrication, foundation, fixing or selected-system drawings follow after system verification.

02

Base/drainage section

Planning reference first. Exact fabrication, foundation, fixing or selected-system drawings follow after system verification.

03

Irrigation plan where relevant

Planning reference first. Exact fabrication, foundation, fixing or selected-system drawings follow after system verification.

04

Goal foundation detail

Planning reference first. Exact fabrication, foundation, fixing or selected-system drawings follow after system verification.

05

Floodlight photometric/structure plan

Planning reference first. Exact fabrication, foundation, fixing or selected-system drawings follow after system verification.

06

Dugout/technical area

Planning reference first. Exact fabrication, foundation, fixing or selected-system drawings follow after system verification.

07

Spectator/venue map

Planning reference first. Exact fabrication, foundation, fixing or selected-system drawings follow after system verification.

08

Maintenance access plan

Planning reference first. Exact fabrication, foundation, fixing or selected-system drawings follow after system verification.

05

EVIDENCE & RELEASE

Keep each evidence type attached to what it actually proves.

01

Governing rule

Defines sport or competition requirements. It does not approve a supplier or local construction detail.

02

Exact product evidence

Testing, approval, certification or manufacturer evidence must match the selected product/configuration.

03

Installed outcome

Where applicable, field/court/facility certification relates to the completed installation rather than the product alone.

04

Project engineering

Foundations, structural supports, wind/seismic, electrical and building interfaces remain project-specific.

05

Commercial release

Quantity, documentation, warranty, freight, installation boundaries, spares and handover are closed before order.

06

MAINTENANCE & HANDOVER

Specify how performance will be maintained.

01

Surface-specific maintenance programme

02

Drainage/irrigation checks

03

Goal/net inspection

04

Infill/brush/decompaction if applicable

05

Line marking

06

Lighting

07

Dugouts/containment

08

Testing / recertification planning

07

TECHNICAL RISK CHECK

Common symptoms that should trigger investigation.

01

Poor drainage / ponding

Investigate profile, drains, outlets, compaction and surface permeability.

02

Artificial turf matting

Review brushing, infill level, fibre condition and usage concentration.

03

Ball roll inconsistent

Review surface condition, infill/moisture, mowing or turf density.

04

Goal instability

Check foundation/anchor/restraint and frame condition.

05

Dark spots under lights

Review aiming, lamp/LED output, dirt, pole position and photometric design.

06

High wear in goalmouth/centre

Adjust maintenance/rotation, repair strategy and training load.

08

PRIMARY GOVERNING REFERENCES

Verify final requirements at the official source.

FIFA Quality Programme for Football Turf

Official FIFA programme separating laboratory testing, installed-field testing and FIFA QUALITY / QUALITY PRO marks.

FIFA Innovation Documents

Current football-turf test manuals, football-goal manual and maintenance guidance.

SUPPLY BOUNDARY

Apollo is supply-only.

Local design, foundations, civil works, installation, electrical work, statutory approvals, accessibility compliance and professional sign-off remain with the appropriate project parties unless a specific support item is expressly included. Current governing-body rules, exact selected-system data and local requirements take precedence over this planning pack.

Project