SOLVARN 33
3 × 3 m · 9 m² nominal footprint
Start Project BriefSolar Outdoor Systems · Project qualification
SOLVARN combines a pergola-format outdoor structure with integrated photovoltaic generation, LiFePO4 battery storage, inverter capacity, LED lighting and powered roof operation. It is designed as a project-configured outdoor energy/shade system rather than a generic off-grid power promise.
Current size family
These are current planning formats. Final post layout, PV module arrangement, structure, wind criteria, controls and exact electrical package remain configuration-specific.
3 × 3 m · 9 m² nominal footprint
3 × 4 m · 12 m² nominal footprint
4 × 4 m · 16 m² nominal footprint
3 × 6 m · 18 m² nominal footprint
4 × 6 m · 24 m² nominal footprint
System architecture
SOLVARN is not presented as “free power”. The project needs to define the actual loads, solar conditions, operating hours, reserve requirements and whether mains charging is available.
Up to 2,000 W theoretical installed PV reference; real yield depends on module layout, shading, orientation and destination solar resource.
Current LiFePO4 48 V / 200 Ah nominal planning reference. Usable energy and reserve policy must be confirmed.
Current 2,000 W continuous / 4,000 W peak planning reference. Exact load compatibility must be checked.
Pergola motor operation can be supported from the battery architecture, subject to exact controls and protection.
LED lighting can be included as a defined project load rather than treated as an afterthought.
Optional mains charging can be coordinated where the destination electrical design supports it.
Applications
Poolside, terrace, guest recreation and destination spaces where shade, lighting and selected off-grid loads can be combined.
Parks, community spaces, recreation areas and civic projects where independent lighting or small auxiliary loads are useful.
Courtside, club, training and spectator-support spaces requiring shade, lighting and selected low-power systems.
Sites where shade and a self-contained power platform can reduce dependence on immediate fixed electrical infrastructure.
Outdoor breakout, waiting, hospitality and amenity areas requiring architectural shade with integrated energy capability.
Outdoor living spaces where integrated solar, lighting and powered roof functions form part of the architecture.
Planning reference
| System | Current planning reference | Control |
|---|---|---|
| PV array | Up to 2,000 W theoretical installed PV reference | Final module layout, orientation, shading and destination solar conditions control real yield. |
| Battery | LiFePO4 48 V / 200 Ah nominal reference | Nominal stored energy is approximately 9.6 kWh before system losses and any operating reserve; usable energy must be confirmed for the final configuration. |
| Inverter | 2,000 W continuous / 4,000 W peak reference | Loads, surge requirements and operating logic must be checked against the exact supplied inverter. |
| Pergola operation | Pergola motor can operate from the battery system | Final controls, motor load and protection remain configuration-specific. |
| Lighting | Integrated LED pathway | Lighting load, controls and daily operating schedule form part of the energy brief. |
| Mains charging | Optional mains-charge pathway | Destination voltage/frequency, charger arrangement and electrical installation require local review. |
| Ingress protection | PV IP67 · inverter/battery IP54 · system IP55 planning references | Ratings must be confirmed against the exact components and installation condition. |
| Wind | 150 km/h design target | Target only; final structural suitability requires exact configuration, site wind criteria, foundations and project engineering. |
Start with the load brief