Apollo NZ GlobalPlan an ARKEN Project
ARKENArchitectural Louvre Systems

ARKEN Technical Centre

Reference data for early system selection and project planning.

ARKEN is Apollo NZ Global's premium architectural louvre platform. Use this technical centre to compare system pathways, reference dimensions, configuration options and the information needed for a project brief. Final project specifications are confirmed against the selected system and current project documentation.

Back to ARKEN

ARKEN · technical diagrams

Understand the system before choosing the configuration.

These diagrams explain system logic rather than represent a final shop drawing. Dimensions, sections, drainage outlets, motors, fixings and enclosure interfaces are confirmed against the selected project platform.

01

System anatomy

Louvres, perimeter beam, posts, drive zone, gutter and drainage work as one coordinated structure.

Adjustable louvre fieldPerimeter beam + gutterStructural postsInternal water route
02

Rotate + retract

The flagship open-sky pathway changes both blade angle and roof coverage.

CLOSEDROTATEDRETRACTED
Closed shelterControlled sun + airflowSubstantially open sky
03

Rainwater route

Closed louvres direct roof water to the perimeter system, then down nominated drainage posts.

Louvre channelsPerimeter gutterNominated drainage postSite discharge by local project team
04

Configuration logic

Freestanding, attached, inset and linked multi-bay layouts solve different structural interfaces.

FREESTANDINGATTACHEDINSETMULTI-BAY
Independent frameBuilding-supported edgeExisting-frame integrationLinked engineered bays
05

Glass + screen integration

Tracks, glass, drainage and screen zones should be coordinated before manufacture.

Beam / track zoneSliding glass panelsCompatible guided-screen zoneThreshold + drainage interface
06

Reference bay planning

Published sizes are useful planning references, not final structural drawings.

4 × 6 m reference4 × 10 m dual-bay reference4.5 × 7 m reference9 × 6.5 m reference
Reduced-column referenceDual-bay referenceHeavy-duty rain pathwayProject engineering controls final geometry

System selection matrix

Choose the engineering pathway from the project requirement.

ARKEN pathwayPremium rotating

Variable project platform
Use when the roof needs controlled shade, ventilation and closed-roof rain management without full roof retraction.

ARKEN pathwayReduced-column rotating

4 × 6 m single · 4 × 10 m dual / 6 posts
Use when wider views and fewer posts are a priority. Current pathways include manual, motorised and smartphone operation.

ARKEN pathwayHeavy-duty rain pathway

4.5 × 7 m / 4 posts · 9 × 6.5 m / 6 posts
Use when larger bays and stronger rain-management geometry are key project drivers.

ARKEN pathwayRetractable open-sky

4 × 6 m / 4-post published reference
Use when blade rotation alone is not enough and the project needs a substantially open roof condition.

ARKEN pathwayGlass-enclosed

Panels up to W1000 × H2600 mm
Use when greater side-weather separation is required while retaining daylight and views.

Published reference data

Useful figures currently supported by the manufacturer material.

Retractable roof reference4000 × 6000 mm · four posts

Current open-sky manufacturing-platform reference; custom project configurations remain subject to engineering.

Retractable posts150 × 150 × 2.5 mm

Current R600/open-sky platform reference.

Retractable beam + gutter200 × 208 × 2.0 mm

Current published reference.

Retractable blade210 × 45 × 2.0 mm

Current published reference.

Retractable operation0–90° rotation + roof retraction

Motorised roof pathway.

Motor ingress referenceIP44

Current published platform rating; final motor model and destination voltage remain quote-confirmed.

Retractable installationFreestanding · wall-mounted · fit into existing structure

Current open-sky manufacturing-platform pathway.

Retractable finish pathwayAkzoNobel surface-treatment reference

Exact coating build-up, pretreatment and coastal warranty remain project-confirmed.

Reduced-column reference4 × 6 m single · 4 × 10 m dual / 6 posts

Current P6 platform reference.

Reduced-column controlsManual · motorised · smartphone

Current manufacturer-published operation pathways.

Reduced-column sealingBuilt-in louvre rubber seals

Current manufacturer material positions these for improved rain control and reduced wind vibration.

Heavy-duty rain reference4.5 × 7 m / 4 posts · 9 × 6.5 m / 6 posts

Current P8 platform reference.

Heavy-duty drainage designWider blade gutters + wider beam gutters

Current heavy-duty platform is specifically positioned for increased drainage capacity in rainy climates.

Frameless glass panelUp to W1000 × H2600 mm

Current product reference.

Glass build-ups10 / 12 mm tempered · 5 + 1.14 PVB + 5 mm laminated

Current manufacturer reference; final destination safety requirements control.

Glass frame coloursRAL 7016 grey · RAL 9016 white

Current frame-colour references; project-specific finish confirmation still applies.

Options we can plan now

Useful choices already supported without over-specifying the project.

OperationManual · motorised · selected smartphone control

Available on selected rotating pathways; retractable open-sky uses motorised operation.

LightingWarm integrated LED · RGB perimeter pathways

Exact layout, driver and controls remain configuration-specific.

InstallationFreestanding · wall-mounted · inset / retrofit

Existing-frame projects require interface review before release.

EnclosureFrameless / slim-frame glass · VELARIS blind coordination

Glass and blinds are treated as separate systems coordinated with the roof.

FinishPowder-coated aluminium · current AkzoNobel pathway

Exact RAL palette, pretreatment, film thickness and coastal warranty remain project-confirmed.

LayoutSingle bay · reduced-column · multi-bay

Final post count, beam size and structural layout depend on the selected engineering pathway.

Project brief checklist

Information that lets Apollo select the right ARKEN pathway faster.

01Country / destination and project type

Include this where known; early-stage projects can proceed with partial information.

02Overall width × projection × desired height

Include this where known; early-stage projects can proceed with partial information.

03Single-bay or multi-bay intent

Include this where known; early-stage projects can proceed with partial information.

04Freestanding, wall-mounted, inset or retrofit

Include this where known; early-stage projects can proceed with partial information.

05Rotating, rotating + retracting, large-span or glass-enclosed intent

Include this where known; early-stage projects can proceed with partial information.

06Wind, coastal, snow, heavy-rain or high-heat exposure

Include this where known; early-stage projects can proceed with partial information.

07Drainage discharge route and surrounding thresholds

Include this where known; early-stage projects can proceed with partial information.

08Power availability, controls and lighting preference

Include this where known; early-stage projects can proceed with partial information.

09Blinds or glass now / later

Include this where known; early-stage projects can proceed with partial information.

10Finish direction, site photos, drawings and target programme

Include this where known; early-stage projects can proceed with partial information.

Technical project review

Need a specification for an active project?

Send the project brief and Apollo will request the model-specific drawing, structure, controls, finish and supporting documents required for that configuration.

Start ARKEN Project Brief