Skip to main content
Apollo NZ Global
Get a QuoteMy Project
Request Project Pricing
Football training session on artificial sports turf
← Sports Turf Systems
LUTHVAR — Sports & Recreation Systems — People · Places · Performance

Football Turf Systems

Competition to community football surfaces.

Project-configured artificial football turf for stadiums, clubs, academies, schools, training facilities and community fields. Surface selection is based on playing level, use, climate, base, drainage, infill strategy and evidence requirements.

Five project pathways

Start with the use case, then confirm the exact system.

Public product families stay stable while the final technical configuration is matched to the current project evidence and supply route.

01

Football Elite

Higher-performance football pathway for stadium, academy and competition-oriented projects.

Project configured
02

Football Performance

Commercial club and academy pathway balancing playing performance, durability and lifecycle use.

Project configured
03

Football Training

High-use training, school and community pathway structured around repeat use and practical maintenance.

Project configured
04

Football Semi-Fill

Reduced-infill pathway for projects where infill quantity and maintenance strategy are material design considerations.

Project configured
05

Football Non-Infill

Non-infill pathway for selected football and recreation projects, subject to exact performance requirements.

Project configured

Documented turf constructions

Three football turf technical options.

Named reference constructions for project-specific review. FIFA laboratory performance does not automatically certify an installed field.

01

TS DURA 50A1

50 mm pile · 12,000 dtex · 8,820 tufts/m²

FIFA Quality field certificate for Galaneika Football Field, Lamia, Greece (field 1019277), valid 8 Oct 2024–7 Oct 2027. Applies to that installation only; proposed system build-up requires confirmation.

Project-specified · supply only

Request a quote for TS DURA 50A1 →

02

TS MAX 60

60 mm pile · 12,000 dtex · 8,820 tufts/m²

Earlier laboratory evidence is referenced in supplier materials, but a current certificate has not been provided. No current FIFA-certified claim is made for this option.

Project-specified · supply only

Request a quote for TS MAX 60 →

03

TS GLOBAL 60A

60 mm pile · 14,000 dtex · 8,820 tufts/m²

FIFA Quality field certificate for Estadio Municipal Rui Manuel Lima, Portugal (field 1021386), valid 10 Sep 2025–9 Sep 2028. Applies to that installation only; proposed system build-up requires confirmation.

Project-specified · supply only

Request a quote for TS GLOBAL 60A →

Football turf — reference system comparison
CharacteristicTS DURA 50A1TS MAX 60TS GLOBAL 60A
Quoted pile height50 mm60 mm60 mm
Quoted yarn weight12,000 dtex12,000 dtex14,000 dtex
Tuft density8,820/m²8,820/m²8,820/m²
Field evidence suppliedFIFA Quality, Greece; valid to 7 Oct 2027 (field 1019277)No current field certificate suppliedFIFA Quality, Portugal; valid to 9 Sep 2028 (field 1021386)
System infillConfirm tested configurationConfirm tested configurationConfirm tested configuration
New-field certificationSeparate independent installed-field assessment, if required

All three quoted options use composite PP/Leno primary backing and latex secondary backing. Taishan confirms an eight-year manufacturer warranty can be issued for Apollo orders, subject to written coverage and exclusions. Sand is sourced locally rather than exported from China; white line markings and joint tape may be quoted. Product-specific system and certification documentation is confirmed at quotation stage. Infill, shock layer if applicable, base, drainage, installation and evidence requirements must be confirmed for the complete project-specific system.

Infill and system selection

Confirm the tested construction before choosing infill.

Supplier test reports include SBR rubber granules in specific football field constructions. Cork can be considered as a locally sourced alternative, but it is not supplied as a standard Taishan package and changing infill may change the tested performance of the system.

SBR rubber infill

Consider the specified granule grading, loading, shock response, local regulations and handling requirements. Match the proposed infill to the documented system test configuration.

Cork alternative

Available for assessment on a project-specific basis from separate suppliers. Cost, availability, maintenance and any required re-testing must be established before a compliant system is quoted.

Field approval

FIFA Quality and Quality Pro field certificates apply to a particular installed field and validity period. They do not automatically extend to a new field or a changed turf/infill combination.

Football turf quotation checklist

Specify the field dimensions, total turf area, intended playing level and weekly usage, as well as whether the project is a new field or resurfacing an existing one. Include an infill preference, relevant local restrictions, base and drainage status, line-marking layout and whether a shockpad is required.

EvidenceIdentify whether the tender calls for FIFA Quality, Quality Pro or a separate installed-field testMaterialsState carpet-only or carpet plus infill / shockpad; all quantities must match the selected systemLogisticsProvide destination, receiving access and installation responsibility for supply-only pricing

Technical data sheets and manufacturer evidence are reviewed for the exact nominated construction before final quotation. Historical field certificates are not offered as proof of current certification.

Request a football materials quotation →

Selection logic

What determines the right football turf?

Pile height or price alone is not a specification. The selected system needs to work with the users, field construction, climate, maintenance model and evidence pathway.

Playing level

Competition, club, academy, school or community.

Usage intensity

Expected weekly and annual utilisation.

Climate

UV, temperature, rainfall, humidity and exposure.

Infill direction

Conventional, reduced-infill or non-infill.

Shock layer

Selected only where the exact system and project require it.

Base & drainage

New construction, conversion or replacement condition.

Evidence requirement

Governing-body, consultant or tender requirements for the exact system.

Artificial football turf system layers including turf, infill, shock pad, drainage and prepared base

Complete field system

Surface, base and drainage must work together.

Depending on the selected pathway, the field system may include performance infill, stabilising infill, a shock layer, drainage layer, prepared base, perimeter restraint and inlaid line marking. These elements are confirmed as one project system rather than treated as interchangeable parts.

Supply model

LUTHVAR is supplied on a wholesale and project basis. Civil works, drainage construction, installation, testing and local compliance remain project-specific and are confirmed in the project scope.

Project brief

What we need to review a football field.

A stronger brief means a faster and more reliable technical selection.

01Project country / location02Field dimensions03Playing level04Expected usage intensity05New build or replacement06Existing base condition07Drainage status08Infill preference09Shock layer requirement10Certification / tender requirement11Installation responsibility12Target project timing

Technical evidence

Certification follows the exact system.

Where a project requires a governing-body standard, consultant specification or formal field-testing pathway, the exact turf, infill, shock layer and supporting documentation are confirmed for the proposed project system. Certification is not treated as a blanket claim across a product family.

Product literature · PDF

Explore the LUTHVAR Football Turf Systems brochure.

Our three-page A4 brochure introduces the reference football turf options, key product specifications and the project information needed to begin technical selection. Technical details and the final surface configuration are confirmed against the selected system.

Technical note: historic FIFA laboratory passes relate to the named tested systems; an installed field requires its own applicable testing and certification. Complete system composition and warranty terms are confirmed during project review.

Football project brief

Send the field conditions before locking the turf.

We can then identify the appropriate LUTHVAR football pathway and confirm the exact technical configuration at quotation stage.

Start football project brief
Project