Skip to main content
Apollo NZ GlobalStart Project Brief

LYSVAR · BALUSTRADES

Frameless glass balustrade planning.

A clean frameless glass line depends on the hidden structure below it. Fixing substrate, loads, channel/spigot geometry and tolerances should be resolved before glass is ordered.

SHORT ANSWER

Design the support and edge condition before freezing the glass.

Confirm barrier loads, height, glass run, returns, substrate, available fixing zone and architectural edge detail. Then develop the exact LYSVAR LINE glass build-up, fixing system and project engineering around those conditions.

KEY PROJECT POINTS

What should drive the decision.

These are project inputs, not substitute engineering or automatic product approvals.

01

Barrier loading is project- and destination-specific.

02

Base-shoe/channel systems need adequate structure and fixing depth.

03

Edge waterproofing and drainage can conflict with channels.

04

Glass joints and panel tolerances need to be buildable.

05

Handrail/cap requirements depend on the selected system and local rules.

06

Replacement access should be considered during design.

COMPARISON

Use-case fit before product preference.

The table is deliberately directional. Exact configurations still require project and evidence review.

PathwayBest fitWatch closely
Continuous channel / base shoeLong clean balustrade runs with concealed continuous support.Substrate design, waterproofing, drainage, straightness and replacement access.
Point / post-supported pathwayProjects where a conventional support rhythm or different substrate condition is preferable.Visual interruption, local load path and hardware corrosion exposure.
01

Set the barrier geometry

Height, returns, corners, stairs and changes in level should be dimensioned before panelisation.

02

Resolve the base detail

Structure, waterproofing, paving/deck interfaces and drainage need to work with the selected fixing system.

03

Coordinate tolerances

Long glass runs magnify set-out errors. Shop drawings should show panel gaps, end conditions and allowable construction tolerances.

04

Plan replacement

The system should allow a damaged panel to be removed and replaced without unreasonable demolition of adjacent finishes.

PROJECT INPUTS

What to have ready before asking for the exact system.

A stronger brief shortens the gap between product interest and a useful technical/commercial response.

01

Destination

02

Balustrade location

03

Barrier height

04

Glass run

05

Corners/returns

06

Stairs/ramps

07

Design loading

08

Glass build-up intent

09

Fixing system

10

Substrate

11

Waterproofing/drainage

12

Coastal exposure

EVIDENCE BOUNDARY

The final balustrade requires exact glass, hardware and structural evidence.

Use exact-system drawings and project engineering for loads, anchors, channel or hardware, glass build-up and substrate. Architectural appearance alone is not evidence of compliance.

LYSVAR LINEApollo architectural glass-balustrade pathway.

FAQ

Questions project teams usually need answered.

Can a glass balustrade be fixed into any concrete edge?

No. Edge distance, reinforcement, thickness and anchor requirements need project review.

Is a handrail always required?

That depends on the exact system and destination requirements.

Should waterproofing be designed before the channel?

Yes. The channel, membrane, drainage and finished edge detail should be coordinated together.