Skip to main content
Apollo NZ GlobalStart Project Brief

AUVENOR · ENCLOSURE

Integrated outdoor enclosure planning.

The best time to coordinate side enclosure is before the roof structure is frozen. Posts, tracks, glass, lighting and drainage all compete for the same interfaces.

SHORT ANSWER

Design the roof and side enclosure together.

Define which sides need blinds, screens or glazing, the desired open/closed combinations, sill/threshold conditions, controls and drainage. Then coordinate posts, beams, tracks and electrical routes as one AUVENOR assembly.

KEY PROJECT POINTS

What should drive the decision.

These are project inputs, not substitute engineering or automatic product approvals.

01

Side tracks need straight stable structural interfaces.

02

Glass and blinds can require different post tolerances.

03

Roof drainage should not discharge into enclosure tracks.

04

Integrated lighting and motors need concealed service routes.

05

Wind pressures change as sides are enclosed.

06

Maintenance access should remain possible with all systems installed.

01

Map every façade state

Show which sides are open, screened, glazed or closed in everyday, bad-weather and service conditions.

02

Resolve post interfaces

Posts may carry roof loads, blind tracks, glass channels, downpipes and electrical routes; congestion needs early coordination.

03

Keep water out of tracks

Roof runoff and site drainage should be directed away from side-enclosure guides and thresholds.

04

Coordinate controls

Roof and blinds may need separate or grouped control logic with clear local operation and isolation.

PROJECT INPUTS

What to have ready before asking for the exact system.

A stronger brief shortens the gap between product interest and a useful technical/commercial response.

01

Roof system

02

Side enclosure type by side

03

Blind/screen/glass openings

04

Post layout

05

Threshold/sill

06

Drainage/downpipes

07

Lighting

08

Power/control routes

09

Wind exposure

10

Furniture/circulation

11

Service access

12

Maintenance responsibilities

EVIDENCE BOUNDARY

Integrated enclosure performance depends on the combined configuration.

Verify exact roof, blind/screen/glass compatibility, fixing details, wind guidance and controls. Do not assume separate products remain valid when combined without interface review.

AUVENOR Authority CentreProject evidence and drawing framework for integrated AUVENOR systems.

FAQ

Questions project teams usually need answered.

Can side blinds be added later?

Sometimes, but planning tracks, power and structural interfaces at the initial stage usually gives a cleaner result.

Can glass and blinds use the same opening?

Potentially, but post depth, tracks, drainage and clearances need exact-system coordination.

Does enclosure change wind loading?

It can. Closing sides changes pressure conditions and should be reviewed in project engineering.

Project